Finite element analysis and comparison of stress distribution in a varus knee joint specimen before and after virtual surgery

Document Type : Research Paper

Authors

Department of Mechanical Engineering, Faculty of Engineering, University of Birjand, Birjand, Iran

Abstract

Background and aim: In a varus knee, the load balance on two sides of the knee joint is disturbed and the stress applied to the medial side of the joint will be greater than that of a healthy knee. The most common type of surgery to correct the deformity and balance the joint load is surgery called High Tibial Osteotomy.
Materials and method: In this study, a 3D model for a varus knee joint specimen was generated from MRI images. The second sample 3D model is prepared for the same joint after performing a virtual Closed Wedge Osteotomy. For the normal standing position, after loading and solving the problem, the stress distribution in the meniscus and the articular cartilage for both samples is obtained.
Results: The results show that the maximum values of Von Mises stress and Contact Pressure for the varus knee are much higher than the corresponding values for the operated knee. The maximum contact pressure, under a 400 Newtons load applied to the upper end of the femoral head, was 7.821 MPa in the internal meniscus for the preoperative knee and 4.099 MPa for the operated knee in the external meniscus. Also, the maximum von Mises stress for before and after surgery was 6.501 and 3.488 MPa, respectively, both in the inner meniscus.
Conclusion: After simulation and finite elements analysis, the results of stress distribution showed that the stresses find a more suitable distribution after the operation and are closer to the values of a healthy knee.

Keywords

Main Subjects


Alami Harandi B. (2003). Textbook of orthopedics and fractures. Tehran:Tehran University of Medical Sciences, 184-190. (In Persian(
Bae J.Y., Park K.S., Seon J.K., Kwak D.S., Jeon I., Song E.K. (2012) “Biomechanical analysis of the effects of medial meniscectomy on degenerative osteoarthritis”. Medical and Biological engineering and Computing, 50(1): 53-60.
Donahue T.L.H., Hull M.L., Rashid M.M., Jacobs C.R. (2002). “A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact”. Journal of Biomechanical Engineering, 124: 273-80.
Dong C.L., Seong J.B. (2012). “High Tibial Osteotomy”. Knee Surgery & Related Research, 24(2): 61-9.
Dong Y., Hu G., Dong Y., Hu Y., Xu Q. (2014). “The effect of meniscal tears and resultant partial meniscectomies on the knee contact stresses: a finite element analysis”. Computer methods in biomechanics and biomedical engineering, 17(13): 1452-63.
Floyd R.T., Thompson C.W. (2001). Manual of Structural Kinesiology. Boston: McGraw-Hill.
Ilbeigi S., Ahmadi Brooghani S. Y., Nadi M. S. (2021). “The Comparison of the Break Pattern of the Femoral Neck in both Normal and Abnormal Angles (Coxavara, Coxavalga) in Active and Non-Active Postmenopausal Women using Finite Element Method”. journal of advanced sport technology, 2:1-11. (In Persian(
Li G., Lopez O., Rubash H. (2001). “Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis”. J Biomech Eng Trans ASME, 123: 341–6.
Meislin R., Peterson C.F., Fulkerson E.W., Di Cesare P.E. (2005). “Osteotomy about the knee: applications, techniques, and results”. The journal of knee surgery, 18: 258-272.
Nickbakht H., Ahmadi Brooghani S. Y., Arbabi V. (2022) “Finite Element Analysis and Comparison of Stress Distribution in Cartilages and Meniscus of Two Healthy and Varus Knee Specimens”. Scientific Research Journal of Biomedical Engineering, 16(2): 151-160. (In Persian)
Ogden S., Mukherjee D.P., Keating M.E., Ogden A.L., Albright J.A., McCall R.E. (2009). “Changes in Load Distribution in the Knee After Opening-Wedge or Closing-Wedge High Tibial Osteotomy”. The Journal of Arthroplasty, 24: 101-9.
Paley D. (2005). Principles of deformity correction. New York: Springer-Verlag Berlin Heidelberg.
Peña E., Calvo B., Martinez M.A., Doblare M. (2006). “A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint”. J Biomech, 39: 1686-701.
Peña E., Calvo B., Martinez M.A., Palanca D., Doblaré M. (2005). “Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics”. Clinical Biomechanics, 20: 498-507.
Rezaeizadeh A. (2005). “High Tibial Dome Shape Osteotomy for Symptomatic Geno-Varum in Young Adults”. Journal of Iran University of Medical Sciences, 49:77-84. (In Persian(
Tarniţă D., Catana M., Tarnita D.N. (2014). “Modeling and finite element analysis of the human knee joint affected by osteoarthritis”. Key Engineering Materials, 601: 147-50.
Thienkarochanakul K., Javadi A.A., Akrami M., Charnley J.R., Benattayallah A. (2020). “Stress Distribution of the Tibiofemoral Joint in a Healthy Versus Osteoarthritis Knee Model Using Image‑Based Three‑Dimensional Finite Element Analysis”. Journal of Medical and Biological Engineering, 40:409-18.
Wang Y., Fan Y., Zhang M. (2014). “Comparison of stress on knee cartilage during kneeling and standing using finite element models”. Medical Engineering & Physics, 36: 439–47.